{"id":7110,"date":"2022-12-21T16:05:49","date_gmt":"2022-12-21T16:05:49","guid":{"rendered":"https:\/\/afwasakm.afwasa.org\/?p=7110"},"modified":"2022-12-22T17:41:06","modified_gmt":"2022-12-22T17:41:06","slug":"a-non-intrusive-technology-for-network-performance-control","status":"publish","type":"post","link":"https:\/\/afwasakm.afwasa.org\/fr\/a-non-intrusive-technology-for-network-performance-control\/","title":{"rendered":"Une technologie non-intrusive pour le contr\u00f4le de la performance des r\u00e9seaux"},"content":{"rendered":"<p>La d\u00e9bitm\u00e9trie \u00e0 ultrasons est un outil de contr\u00f4le de la performance des r\u00e9seaux et de maintenance pr\u00e9ventive en poste portable et fixe. Le principe de fonctionnement est la pose de deux (02) capteurs du m\u00eame c\u00f4t\u00e9 de la conduite avec \u00e9mission d\u2019une onde sur le c\u00f4t\u00e9 ; cette onde se r\u00e9fl\u00e9chit sur le tuyau qui arrive sur le second capteur. Le 2<sup>nd<\/sup> capteur fait la m\u00eame chose et \u00e9met un signal qui va \u00eatre r\u00e9cup\u00e9r\u00e9 par l\u2019autre capteur. En fonction du sens du flux et de la vitesse, une diff\u00e9rence de temps de trajet sera not\u00e9e, laquelle permet de mesurer la vitesse.<\/p>\n<p>Comme pour tout outil de mesure, il convient de param\u00e9trer le diam\u00e8tre ext\u00e9rieur du tuyau ou l\u2019\u00e9paisseur de paroi et la nature du mat\u00e9riau.<\/p>\n<p>L\u2019avantage du d\u00e9bitm\u00e8tre \u00e0 ultrasons r\u00e9side en sa technologie non intrusive. Il s\u2019adapte \u00e0 l\u2019environnement et se pose sur le tuyau, sans besoin d\u2019effectuer la prise en charge sur la conduite ou la couper. En outre, il n\u2019est pas n\u00e9cessaire d\u2019effectuer des travaux importants pour la pose du d\u00e9bitm\u00e8tre. Ses d\u00e9tecteurs lui permettent de s\u2019adapter \u00e0 diff\u00e9rents types de canalisations, car ils s\u2019ajustent \u00e0 la conduite et peuvent \u00eatre pos\u00e9s sur tous types de r\u00e9seaux, notamment les r\u00e9seaux m\u00e9talliques, non m\u00e9talliques, PVC, PE, b\u00e9ton, ciment, amiante, etc., qui se situent entre 25 et 4700 de diam\u00e8tre.<\/p>\n<p>La mesure est bidirectionnelle et sans perte de charges car il n\u2019y a pas de contact avec de l\u2019eau. Les capteurs peuvent \u00eatre pos\u00e9s \u00e0 des endroits diff\u00e9rents et n\u00e9cessitent peu d\u2019espace en fonction du diam\u00e8tre et de la nature du mat\u00e9riau. L\u2019espacement entre les capteurs n\u2019est pas forc\u00e9ment tr\u00e8s important.<\/p>\n<p>L\u2019outil portable se pr\u00e9sente sous la forme d\u2019un petit objet qui peut tenir dans la main en fonction du fabricant et de la paire de capteurs, dot\u00e9 d\u2019un syst\u00e8me qui permet d\u2019accrocher les capteurs sur la conduite.<\/p>\n<p>Les domaines d\u2019application sont assez vari\u00e9s. La d\u00e9bitm\u00e9trie \u00e0 ultrasons permet de contr\u00f4ler la performance des r\u00e9seaux, en compl\u00e9ment ou alternativement \u00e0 la sectorisation fixe, qui est assez d\u00e9velopp\u00e9e dans le monde. La performance d\u2019un r\u00e9seau d\u2019eau potable est contr\u00f4l\u00e9e par la mesure de son d\u00e9bit, notamment le d\u00e9bit nocturne. La sectorisation permet d\u2019identifier les secteurs fuyards et de prioriser les zones de recherche sur lesquels mener des actions prioritaires de recherche de fuites, de fraudes et de renouvellement de r\u00e9seau, etc.<\/p>\n<p>Les vannes \u00e9tanches permettent de r\u00e9duire davantage les secteurs \u00e0 travers des man\u0153uvres de vannes, des modifications de secteurs hydrauliques dans la nuit, sur plusieurs jours ou en instantan\u00e9 en fonction des zones de recherche. Elles permettent \u00e9galement de quantifier les pertes sur les d\u00e9bits nocturnes, et effectuer ensuite un ratio des pertes pour v\u00e9rifier la performance du r\u00e9seau dans les concern\u00e9es afin d\u2019enclencher ou non des actions correctrices. Elles sont encore utilis\u00e9es pour v\u00e9rifier la sectorisation en place, notamment les gros compteurs et d\u00e9bitm\u00e8tres qui sont d\u00e9j\u00e0 en postes fixes, qui constitue un axe strat\u00e9gique pour les exploitants des r\u00e9seaux d\u2019eau. Le contr\u00f4le est r\u00e9alis\u00e9 d\u00e8s l\u2019insertion, gr\u00e2ce \u00e0 la pr\u00e9sence d\u2019un capteur fixe qui n\u00e9cessite une prise en charge et au moyen d\u2019un d\u00e9bitm\u00e8tre \u00e0 ultrasons, qui peut \u00eatre un d\u00e9bitm\u00e8tre \u00e9lectromagn\u00e9tique, un compteur m\u00e9canique, etc.<\/p>\n<p>Certains clients l\u2019utilisent pour v\u00e9rifier les gros compteurs des gros consommateurs avant la validation du comptage, compte tenu de l\u2019impact financier du sous-comptage chez les gros consommateurs.<\/p>\n<p>Les donn\u00e9es provenant de la v\u00e9rification des compteurs de sectorisation fixe sont utilis\u00e9es pour l\u2019analyse du bon ou mauvais fonctionnement d\u2019un r\u00e9seau. Le d\u00e9faut de prise de mesure sur le compteur fixe a des r\u00e9percussions sur l\u2019exploitation et la performance des r\u00e9seaux. Pour v\u00e9rifier les d\u00e9bits de pompe, il convient de placer les capteurs sur les conduites en sortie de pompe et valider le d\u00e9bit nominal de la pompe, c\u2019est-\u00e0-dire d\u00e9finir si la pompe fonctionne correctement ou s\u2019il y a besoin de maintenance.<\/p>\n<p>On peut s\u2019en servir en amont des travaux lors de la d\u00e9finition des profils de consommation et distribution, d\u2019un suppresseur ou de renouvellement de conduites. Il est possible de poser l\u2019appareil sur plusieurs jours afin de faire des enregistrements des d\u00e9bits minimums, maximums et moyens qui permettent de dimensionner correctement les travaux (Ex.\u00a0: \u00e9viter d\u2019avoir des tuyaux ou canalisations trop importantes ou trop petites, avoir un suppresseur adapt\u00e9 \u00e0 la zone).<\/p>\n<p>Les images contenues dans la pr\u00e9sentation ci-dessous montrent le d\u00e9marrage successif de quatre pompes pour atteindre le d\u00e9bit souhait\u00e9 en tirage pour faire les contr\u00f4les, et diff\u00e9rents exemples de mise en \u0153uvre. Dans le premier exemple, la sonde \u00e0 insertion \u00e0 poste fixe transmet ses donn\u00e9es via un syst\u00e8me de transmission \u00e0 distance sur logiciel de supervision de clients. L\u2019\u00e9quipe de recherche de fuites du client avait effectu\u00e9 \u00e0 trois reprises une recherche de 20m<sup>3<\/sup> de fuites sur un secteur pr\u00e9cis, sans succ\u00e8s. Revenus au point de d\u00e9part, il y\u2019avait un d\u00e9calage de 20m<sup>3<\/sup> entre le d\u00e9bitm\u00e8tre \u00e0 ultrasons portable qui a \u00e9t\u00e9 pos\u00e9 et la sonde \u00e0 insertion. La d\u00e9rive de la sonde \u00e0 insertion qui s\u2019est produite a entra\u00een\u00e9 une erreur de calcul par rapport \u00e0 un point de mesure et par cons\u00e9quent une perte d\u2019exploitation due au temps pass\u00e9 \u00e0 chercher des fuites l\u00e0 o\u00f9 il n\u2019y en avait pas.<\/p>\n<p>En ce qui concerne la comparaison avec des d\u00e9bitm\u00e8tres \u00e9lectromagn\u00e9tiques, l\u2019accord avec le d\u00e9bitm\u00e8tre en place peut parfois bien se passer, mais on peut aussi observer des d\u00e9fauts du parasitage \u00e9lectromagn\u00e9tique sur le compteur \u00e9lectromagn\u00e9tique qui conduisent \u00e0 un d\u00e9faut de comptage et une action corrective du client. Dans l\u2019un des cas observ\u00e9s, l\u2019un des compteurs \u00e9lectromagn\u00e9tiques avait eu un gros d\u00e9bit de fuites, et le doute de fuites persistait. Effectivement, il y avait 4 \u00e0 5m\u00e8tres cubeur d\u2019\u00e9cart qui emp\u00eachaient de trouver l\u2019emplacement de la fuite, car le client ne se retrouvait pas dans sa sectorisation. La pose d\u2019un d\u00e9bitm\u00e8tre \u00e0 ultrasons a permis d\u2019identifier le probl\u00e8me assez rapidement. L\u2019exemple 2 (voir la pr\u00e9sentation) est une conduite en acier inox DN300 sur site sur lequel il fallait v\u00e9rifier un d\u00e9bit de pompe. Plus la conduite sera importante, plus il y aura de l\u2019espacement entre les capteurs. En cas d\u2019absence de d\u00e9bitm\u00e8tre fixe, il est possible d\u2019utiliser le d\u00e9bitm\u00e8tre \u00e0 ultrasons portable comme point de d\u00e9part pour effectuer des op\u00e9rations de v\u00e9rification de fuites, de fraudes et valider le bon fonctionnement du r\u00e9seau. Pour rappel, le d\u00e9bitm\u00e8tre minimum est reli\u00e9 au lin\u00e9aire de r\u00e9seau existant.<\/p>\n<p>Cet outil de mesure portable s\u2019adresse \u00e0 des services diff\u00e9rents: le service distribution, performances et r\u00e9seaux peut s\u2019int\u00e9resser \u00e0 la fonctionnalit\u00e9 de recherche de fuites, mesure de d\u00e9bit et ratio indice lin\u00e9aire de pertes\u00a0; le service production et maintenance peut l\u2019utiliser pour valider les d\u00e9bits de pompe entre autres \u00e9l\u00e9ments qui sortent de l\u2019usine\u00a0; le service m\u00e9trologie et comptage pour la v\u00e9rification de compteurs \u00e0 poste fixe\u00a0; le service bureau d\u2019\u00e9tude et travaux pour la r\u00e9alisation de profit hydraulique en amont de travaux (ex.\u00a0: modification de conduites, suppresseurs, etc.)\u00a0; et le service qualit\u00e9 pour valider la performance du r\u00e9seau, etc.<\/p>\n<p>Le cadre d\u2019utilisation du d\u00e9bitm\u00e8tre \u00e0 ultrasons \u00e0 poste fixe est diff\u00e9rent. L\u2019outil portable est multiservice et s\u2019adapte \u00e0 l\u2019environnement. L\u2019utilisation du poste fixe s\u2019av\u00e8re plus contraignante, compte tenu de la n\u00e9cessit\u00e9 d\u2019\u00eatre attach\u00e9 \u00e0 un point. Les capteurs sont les m\u00eames pour le poste portable et pour le fixe. La diff\u00e9rence r\u00e9side au niveau de l\u2019unit\u00e9, qui sera fixe et \u00e0 proximit\u00e9 de la paire de capteurs pour la r\u00e9cup\u00e9ration des donn\u00e9es des capteurs et la communication de liaison avec le syst\u00e8me de transmission \u00e0 distance pour la retransmission sur un logiciel de supervision. L\u2019int\u00e9r\u00eat est manifeste lorsqu\u2019il s\u2019agit de gros diam\u00e8tres (minimum DM400). En dessous de cette taille, il est possible de recourir au poste fixe lorsqu\u2019il s\u2019agit de g\u00e9rer une canalisation fragile qu\u2019on ne souhaite pas toucher (l\u2019int\u00e9r\u00eat ici r\u00e9side dans le cot\u00e9 non-intrusif et l\u2019absence de travaux importants pour la pose de l\u2019\u00e9quipement). Toutefois, il convient d\u2019\u00eatre rigoureux sur les longueurs droites \u00e0 respecter pour une meilleure pr\u00e9cision \u00e0 long terme.<\/p>\n<p>Le d\u00e9bitm\u00e8tre \u00e0 ultrasons est utilis\u00e9 aussi bien pour l\u2019eau potable que pour l\u2019eau us\u00e9e, car les d\u00e9bits de pompe de relevage sont \u00e9galement v\u00e9rifi\u00e9s par les services d\u2019assainissement. La v\u00e9rification de d\u00e9bit de pompes de refoulement \u00e0 postes fixes s\u2019effectue \u00e9galement pour les eaux us\u00e9es. Pour obtenir la pr\u00e9cision de mesure de l\u2019eau us\u00e9e au moyen du d\u00e9bitm\u00e8tre \u00e0 ultrasons, la conduite doit \u00eatre pleine. Des capteurs peuvent \u00eatre enterr\u00e9s et immerg\u00e9s tr\u00e8s longtemps sur des postes fixes. Les pompes avec variateurs permettent de tester des mesures de d\u00e9bit, m\u00eame dans le cas o\u00f9 l\u2019eau est charg\u00e9e.<\/p>\n<p>D\u2019origine allemande, SEWERIN est un fabricant de mat\u00e9riel d\u2019am\u00e9lioration de performances des r\u00e9seaux d\u2019eau, notamment de recherche de fuites d\u2019eau et d\u2019am\u00e9lioration de l\u2019Eau Non Factur\u00e9e (ENF).<\/p>\n<p>&nbsp;<\/p>\n<div  class='avia-button-wrap av-av_button-7807d64fb1a926c42bf6de50af7ec1ff-wrap avia-button-center  avia-builder-el-0  avia-builder-el-no-sibling '><a href='https:\/\/afwasakm.afwasa.org\/wp-content\/uploads\/2022\/12\/PRESENTATION_DEBIMETRIE_SEWERIN_DEC22.pdf'  class='avia-button av-av_button-7807d64fb1a926c42bf6de50af7ec1ff av-link-btn avia-icon_select-yes-left-icon avia-size-medium avia-position-center avia-color-theme-color'   aria-label=\"T\u00e9l\u00e9charger ici\"><span class='avia_button_icon avia_button_icon_left' aria-hidden='true' data-av_icon='\ue82d' data-av_iconfont='entypo-fontello'><\/span><span class='avia_iconbox_title' >T\u00e9l\u00e9charger ici<\/span><\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>La d\u00e9bitm\u00e9trie \u00e0 ultrasons est un outil de contr\u00f4le de la performance des r\u00e9seaux et de maintenance pr\u00e9ventive en poste portable et fixe. Le principe de fonctionnement est la pose de deux (02) capteurs du m\u00eame c\u00f4t\u00e9 de la conduite avec \u00e9mission d\u2019une onde sur le c\u00f4t\u00e9 ; cette onde se r\u00e9fl\u00e9chit sur le tuyau [&hellip;]<\/p>\n","protected":false},"author":17,"featured_media":7119,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[3,60,110,107],"tags":[],"class_list":["post-7110","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-water","category-eaux-usees","category-technologies-de-gestion-de-leau"],"translation":{"provider":"WPGlobus","version":"3.0.0","language":"fr","enabled_languages":["en","fr"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"fr":{"title":true,"content":true,"excerpt":false}}},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v25.3.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Une technologie non-intrusive pour le contr\u00f4le de la performance des r\u00e9seaux - Association Africaine de L&#039;Eau Gestion et partage des connaissances<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Une technologie non-intrusive pour le contr\u00f4le de la performance des r\u00e9seaux - Association Africaine de L&#039;Eau Gestion et partage des connaissances\" \/>\n<meta property=\"og:url\" content=\"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/\" \/>\n<meta property=\"og:site_name\" content=\"Association Africaine de L&#039;Eau Gestion et partage des connaissances\" \/>\n<meta property=\"article:published_time\" content=\"2022-12-21T16:05:49+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-12-22T17:41:06+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/afwasakm.afwasa.org\/wp-content\/uploads\/2022\/12\/COUVERTURE_DEBIMETRIE-PAR-SEWERIN_001.png\" \/>\n\t<meta property=\"og:image:width\" content=\"842\" \/>\n\t<meta property=\"og:image:height\" content=\"595\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Sonia Fotsing TEGANTCHOUANG\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Sonia Fotsing TEGANTCHOUANG\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"16 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/\",\"url\":\"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/\",\"name\":\"Une technologie non-intrusive pour le contr\u00f4le de la performance des r\u00e9seaux - Association Africaine de L&#039;Eau Gestion et partage des connaissances\",\"isPartOf\":{\"@id\":\"https:\/\/afwasakm.afwasa.org\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/afwasakm.afwasa.org\/wp-content\/uploads\/2022\/12\/COUVERTURE_DEBIMETRIE-PAR-SEWERIN_001.png\",\"datePublished\":\"2022-12-21T16:05:49+00:00\",\"dateModified\":\"2022-12-22T17:41:06+00:00\",\"author\":{\"@id\":\"https:\/\/afwasakm.afwasa.org\/fr\/#\/schema\/person\/5d8d482ddfa45300833879b44eae2a87\"},\"breadcrumb\":{\"@id\":\"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/#primaryimage\",\"url\":\"https:\/\/afwasakm.afwasa.org\/wp-content\/uploads\/2022\/12\/COUVERTURE_DEBIMETRIE-PAR-SEWERIN_001.png\",\"contentUrl\":\"https:\/\/afwasakm.afwasa.org\/wp-content\/uploads\/2022\/12\/COUVERTURE_DEBIMETRIE-PAR-SEWERIN_001.png\",\"width\":842,\"height\":595},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/afwasakm.afwasa.org\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"A Non-Intrusive Technology for Network Performance Control\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/afwasakm.afwasa.org\/fr\/#website\",\"url\":\"https:\/\/afwasakm.afwasa.org\/fr\/\",\"name\":\"African Water And Sanitation Association Knowledge Management\",\"description\":\"Association Africaine de L&#039;Eau Gestion et partage des connaissances\",\"alternateName\":\"AfWASA\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/afwasakm.afwasa.org\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/afwasakm.afwasa.org\/fr\/#\/schema\/person\/5d8d482ddfa45300833879b44eae2a87\",\"name\":\"Sonia Fotsing TEGANTCHOUANG\",\"sameAs\":[\"https:\/\/afwakm.afwa-hq.org\"],\"url\":\"https:\/\/afwasakm.afwasa.org\/fr\/author\/sfotsing\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Une technologie non-intrusive pour le contr\u00f4le de la performance des r\u00e9seaux - Association Africaine de L&#039;Eau Gestion et partage des connaissances","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/","og_locale":"fr_FR","og_type":"article","og_title":"Une technologie non-intrusive pour le contr\u00f4le de la performance des r\u00e9seaux - Association Africaine de L&#039;Eau Gestion et partage des connaissances","og_url":"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/","og_site_name":"Association Africaine de L&#039;Eau Gestion et partage des connaissances","article_published_time":"2022-12-21T16:05:49+00:00","article_modified_time":"2022-12-22T17:41:06+00:00","og_image":[{"width":842,"height":595,"url":"https:\/\/afwasakm.afwasa.org\/wp-content\/uploads\/2022\/12\/COUVERTURE_DEBIMETRIE-PAR-SEWERIN_001.png","type":"image\/png"}],"author":"Sonia Fotsing TEGANTCHOUANG","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Sonia Fotsing TEGANTCHOUANG","Dur\u00e9e de lecture estim\u00e9e":"16 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/","url":"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/","name":"Une technologie non-intrusive pour le contr\u00f4le de la performance des r\u00e9seaux - Association Africaine de L&#039;Eau Gestion et partage des connaissances","isPartOf":{"@id":"https:\/\/afwasakm.afwasa.org\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/#primaryimage"},"image":{"@id":"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/#primaryimage"},"thumbnailUrl":"https:\/\/afwasakm.afwasa.org\/wp-content\/uploads\/2022\/12\/COUVERTURE_DEBIMETRIE-PAR-SEWERIN_001.png","datePublished":"2022-12-21T16:05:49+00:00","dateModified":"2022-12-22T17:41:06+00:00","author":{"@id":"https:\/\/afwasakm.afwasa.org\/fr\/#\/schema\/person\/5d8d482ddfa45300833879b44eae2a87"},"breadcrumb":{"@id":"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/#primaryimage","url":"https:\/\/afwasakm.afwasa.org\/wp-content\/uploads\/2022\/12\/COUVERTURE_DEBIMETRIE-PAR-SEWERIN_001.png","contentUrl":"https:\/\/afwasakm.afwasa.org\/wp-content\/uploads\/2022\/12\/COUVERTURE_DEBIMETRIE-PAR-SEWERIN_001.png","width":842,"height":595},{"@type":"BreadcrumbList","@id":"https:\/\/afwasakm.afwasa.org\/a-non-intrusive-technology-for-network-performance-control\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/afwasakm.afwasa.org\/"},{"@type":"ListItem","position":2,"name":"A Non-Intrusive Technology for Network Performance Control"}]},{"@type":"WebSite","@id":"https:\/\/afwasakm.afwasa.org\/fr\/#website","url":"https:\/\/afwasakm.afwasa.org\/fr\/","name":"African Water And Sanitation Association Knowledge Management","description":"Association Africaine de L&#039;Eau Gestion et partage des connaissances","alternateName":"AfWASA","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/afwasakm.afwasa.org\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Person","@id":"https:\/\/afwasakm.afwasa.org\/fr\/#\/schema\/person\/5d8d482ddfa45300833879b44eae2a87","name":"Sonia Fotsing TEGANTCHOUANG","sameAs":["https:\/\/afwakm.afwa-hq.org"],"url":"https:\/\/afwasakm.afwasa.org\/fr\/author\/sfotsing\/"}]}},"jetpack_featured_media_url":"https:\/\/afwasakm.afwasa.org\/wp-content\/uploads\/2022\/12\/COUVERTURE_DEBIMETRIE-PAR-SEWERIN_001.png","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/afwasakm.afwasa.org\/fr\/wp-json\/wp\/v2\/posts\/7110","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/afwasakm.afwasa.org\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/afwasakm.afwasa.org\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/afwasakm.afwasa.org\/fr\/wp-json\/wp\/v2\/users\/17"}],"replies":[{"embeddable":true,"href":"https:\/\/afwasakm.afwasa.org\/fr\/wp-json\/wp\/v2\/comments?post=7110"}],"version-history":[{"count":7,"href":"https:\/\/afwasakm.afwasa.org\/fr\/wp-json\/wp\/v2\/posts\/7110\/revisions"}],"predecessor-version":[{"id":7145,"href":"https:\/\/afwasakm.afwasa.org\/fr\/wp-json\/wp\/v2\/posts\/7110\/revisions\/7145"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/afwasakm.afwasa.org\/fr\/wp-json\/wp\/v2\/media\/7119"}],"wp:attachment":[{"href":"https:\/\/afwasakm.afwasa.org\/fr\/wp-json\/wp\/v2\/media?parent=7110"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/afwasakm.afwasa.org\/fr\/wp-json\/wp\/v2\/categories?post=7110"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/afwasakm.afwasa.org\/fr\/wp-json\/wp\/v2\/tags?post=7110"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}